Description
Installation Parameters
Galvanized Anchore Installation Parameters  | Performances  | ||||||
M6  | M8  | M10  | M12  | M14  | M16  | M20  | |
dₒ Nominal diameter of drill bit: [mm]  | 6  | 8  | 10  | 12  | 14  | 16  | 20  | 
d𝒻 Fixture clearance hole diameter: [mm]  | 7  | 9  | 12  | 14  | 16  | 18  | 22  | 
Tᵢₙₛₜ Nominal installation torque: [Nk]  | 7  | 20  | 35  | 60  | 90  | 120  | 240  | 
Standard embedment depth  | |||||||
Lₘᵢₙ Total length of the bolt :   [mm]                      | 60  | 75  | 85  | 100  | 120  | 125  | 160  | 
Lₘₐₓ Total length of the bolt : [mm]  | 180  | 155  | 230  | 250  | 250  | 280  | 270  | 
hₘᵢₙ Minimux thickness of concrete member: [mm]  | 100  | 100  | 110  | 130  | 150  | 168  | 206  | 
h₁ Depth of drilled hole: [mm]  | 55  | 65  | 75  | 85  | 100  | 110  | 135  | 
hₙₒₘ Overall anchor embed deth in concrete: [mm]  | 49.5  | 59.5  | 66.5  | 77  | 91  | 103.5  | 125  | 
hₑ𝒻,ₛₜ𝒹  Effective anchorage depth:  [mm]  | 40  | 48  | 55  | 65  | 75  | 84  | 103  | 
t𝒻ᵢₓ thickness of fixture [mm]  | L-58  | L-70  | L-80  | L-92  | L-108  | L-122  | L-147  | 
Sₘᵢₙ Minimum allowable spacing: [mm]  | 50  | 65  | 70  | 85  | 100  | 110  | 135  | 
Cₘᵢₙ Minimum allowable distance: [mm]  | 50  | 65  | 70  | 85  | 100  | 110  | 135  | 
Reduced embedment depth  | |||||||
Lₘᵢₙ Total length of the bolt : [mm]  | --  | 60  | 70  | 80  | --  | --  | --  | 
Lₘₐₓ Total length of the bolt : [mm]  | --  | 155  | 230  | 250  | --  | --  | --  | 
hₘᵢₙ Minimux thickness of concrete member: [mm]  | --  | 100  | 100  | 100  | --  | --  | --  | 
h₁ Depth of drilled hole: [mm]  | --  | 50  | 60  | 70  | --  | --  | --  | 
hₙₒₘ Overall anchor embed deth in concrete: [mm]  | --  | 46.5  | 53.5  | 62  | --  | --  | --  | 
hₑ𝒻,ₛₜ𝒹 Effective anchorage depth: [mm]  | --  | 35  | 42  | 50  | --  | --  | --  | 
t𝒻ᵢₓ thickness of fixture [mm]  | --  | L-57  | L-67  | L-77  | --  | --  | --  | 
Sₘᵢₙ Minimum allowable spacing: [mm]  | --  | 65  | 70  | 85  | --  | --  | --  | 
Cₘᵢₙ Minimum allowable distance: [mm]  | --  | 65  | 70  | 85  | --  | --  | --  | 
Technical Data
Galvanized Anchore Displacement under tension load in C20/25 to C50/60 concrete  | Performances  | ||||||
M6  | M8  | M10  | M12  | M14  | M16  | M20  | |
Standard embedment depth  | |||||||
Tension load in non cracked concrete: [kN]  | 2.8  | 5.0  | 6.0  | 9.3  | 10.7  | 16.0  | 17.0  | 
∆SN₀ Displacement: [mm]  | 0.70  | 1.12  | 1.07  | 1.32  | 1.82  | 2.38  | 3.56  | 
∆SN∞ Displacement: [mm]  | 1.47  | 2.34  | 2.24  | 2.77  | 3.82  | 4.99  | 7.47  | 
Reduced embedment depth  | |||||||
Tension load in non cracked concrete: [kN]  | --  | 4.2  | 5.7  | 7.6  | --  | --  | --  | 
∆SN₀ Displacement: [mm]  | --  | 0.20  | 0.13  | 0.06  | --  | --  | --  | 
∆SN∞ Displacement: [mm]  | --  | 1.78  | 1.78  | 1.78  | --  | --  | --  | 